Siemens Fire Alarm System

Leading Service Provider of siemens cerberus pro modular fcm2041-u3 system advanced addressable fire alarm control panel, siemens cab1, cerberus pro modular enclosure - one row system enclosure, siemens psc-12m, cerberus pro power supply, siemens ccl - can cable (controller-area network) cerberus pro modular system, siemens fc924 us cerberus pro 504-points addressable fire alarm control panel and siemens fhk2002-r3 enclosure kit 2 height units 1 window red (for fc922 fc924) from Gurugram.

Siemens Cerberus Pro Modular FCM2041-U3 System Advanced Addressable Fire Alarm Control Panel

Request Callback

₹ 82500 / Piece Get Latest Price

View Brochure
Number of Zone8
MaterialSheet Metal
Operating Voltage120VAC – 240VAC @ 50 / 60Hz
Operating Current12A of basic system power; expandable to 48A
BrandSiemens
ColourBlack
Loop Capacity10 Loops
Display Type6-inch (15.2 cm.), backlit liquid-crystal display (LCD) - Multi-language display
OperationStandard / 2500-point-capacity addressable fire-alarm control panel (FACP)
User InterfaceTouch screen for maintenance operations and function keys
InstallationAvailable on extra charges

Minimum order quantity: 1 Piece

  • Standard / 2500-point-capacity addressablefire-alarm control panel (FACP)
  • Ability to network with other Cerberus PRO Modular (Cerberus PRO Modular) systems
  • Powerful, easy-to-use programming capabilities Multiple levels of password protection
  • Fully programmable through use of a Windows operating system
  • 6-inch (15.2 cm.), backlit liquid-crystal display (LCD) - Multi-language display
  • User-friendly system interface - Useful diagnostic light-emitting diodes (LEDs) on all cards
  •  Touch screen for maintenance operations and function keys
  •  Menu-driven operator commands - End-user HELP screens
  • 32-character custom messages- 40 programmable macro and function buttons – (e.g. –Holiday schedule)
  • Global annunciation and control capability
  • Alarm' | `Trouble' | `Programmable', etc.
  • relay commands
  • Alarm verification by device, zone - Pre-alarm operation
  • SureWire™ addressable-loop technology: - Patented polarity-insensitive detection circuits
  • Supports FirePrint® application-specific detection, and single-person `Walk Test'
  • Coded outputs
  • Seismic certified
  • Modular assembly
  • Distributed processing
  • UUKL Listed for smoke control

System Overview –

Each panel complies with the requirements of NFPA Standard 72, and is listed by Underwriters Laboratories under their UL 864 standard and is FM Approved.Underwriters Laboratories Canada also lists Cerberus PRO Modular panels under ULC-S527. Each panel is additionally UL Listed under
the category `UUKL for Smoke Control.' When it comes to Siemens Sinorix® clean- agent systems, Cerberus PRO Modular panels are UL | ULC Listed, which includes for use in foam or water applications. Each panel is also listed as a Fireman's Smoke Control Station (in high-rise office buildings | malls | other large structures. Cerberus PRO Modular has been seismic qualified in accordance with: − International Building Code | 2006 Ed.
− California Building Code | 2007 Ed.− ASCE Standard 7 | 2005 Ed. − OSHPD, OSP-0057-10 − OSHPD, CAN 2-1708A.5, Rev. 3 − ICC-ES AC 156, effective 1/1/2007
Architect & Engineer Specifications
  • Universal AC power input: - 120VAC – 240VAC @ 50 / 60Hz - 12A of basic system power; expandable to 48A
  • Supported by all Cerberus® DMS Management Stations
  • Automatic environmental compensation for smoke detectors
  • Peripheral interface to remote printers - connected to the communication bus from any NIC-C output in an enclosure - Class B (Style 4) or Class A (Style 7) wiring
  • Security-device monitoring - UL1076 Listed
  • Mounts in one (1) electrical back box - Optional 4–11/16 inch [12 cm.] and 5- inch [12.7 cm.] square back boxes
  • Supports pre-action | deluge | agent releasing - sprinkler supervision
  • NEC 760 power-limited circuits
  • 200 notification-appliance-circuits (NACs) capacity - Up to 3A @ 24VDC per NAC - Built-in strobe synchronization protocol
  • UL 864 10th Edition and UL 2572 Listed, ULC-S527 3rd Edition Listed; FM, CSFM Approved

Siemens CAB1, Cerberus PRO Modular Enclosure - One Row System Enclosure

Request Callback

₹ 44000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
Backup BatteryEnclosures can also mount system backup batteries up to 31AH in capacity.
SizeApproximate size is 27" (68.6cm.) high; 26" (66cm.) wide, and 8" (20.3cm.) deep.
TypeOne Row Enclosure
CertificationUL 864 Listed, ULC Listed
ColourBlack

Minimum order quantity: 1 Piece

- The enclosures used with Cerberus PRO Modular systems (Models CAB1), along with their accessories, provide a complete set of hardware for mounting all main system and remote transponder cards and modules.

- The hardware allows each Modular system to be configured for a wide variety of applications.

- Included in the enclosure series are backbox and door sets; removable mounting plates and clear lenses; louvered ventilation grill plates, and blank plates for use with the enclosure doors.

- All enclosures come with ground straps for the inner and outer doors; shield termination lugs; grounding lugs, and tie wrap lances for securing wire.

- All enclosures can also mount system backup batteries up to 31AH in capacity.

- Single-Row Enclosure Model CAB1, the smallest of the Cerberus PRO Modular system enclosures, can house a single Model CAB-MP cabinet mounting plate for mounting card cages, power supplies and bulk amplifiers.

- Model CAB1 also has four (4) mounting slots on the inner door for mounting an Operator Interface (OI) and Model ID-MP switch module brackets.

- Each Model CAB1 comes complete with a black back box, with black inner and outer doors, a single lock and-key set on the outer door, and a single OD-LP outer door lens plate (installed).

Siemens PSC-12M, Cerberus PRO Power Supply

Request Callback

₹ 69900 / Piece Get Latest Price

View Brochure
Model NamePSC 12M
Output Voltage220 V
24VDC Back Plane Current2.0A, max.
24V Standby Current150mA plus 20mA per active relay
Built-in Battery ChargerCapable of charging up to 100AH batteries

Minimum order quantity: 1 Piece

The Model PSCPSC-12M Power Power-Supply Charger is a high high-current power supply that provides a Cerberus PRO Modular panel with primary, regulated 24VDC power to operate at 12 Amps (`Alarm’ mode) / 5 Amps (`Standby’).

With its built built-in battery charger – capable of c harging up to 100AH batteries, Model PSC PSC-12M is an addressable addressable-intelligent, microprocessor microprocessor-controlled power module that communicates its status to the Cerberus PRO Modular Operator Interface (OI), ModelFCM2041FCM2041-U3. Moreover, the panel’s OI is able to quer y the status of the power supply to obtain data regarding system system-charging current | terminal terminal-loading information | ground faultfault-conditions and more.

PSC-12M is a universal power supply, accepting AC power power-input levels from 120VAC – 240VAC @ 50 / 60Hz . No special configuration is required: Model PSC PSC-12M is designed to operate across these AC input ranges. A 60 60-pin connector is used for communication between a Model PSC PSC-12M charger and other system cards andmodules. The communication transmission ( of which has variables of 6.2VDC and 24VDC), is referred as `back back-plane current’.

Siemens CCL - CAN Cable (Controller-area network) Cerberus PRO Modular System

Request Callback

₹ 1200 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeCAN CABLE
StandardUL / ULC Listed; FM, CSFM Approved
Net Weight0.910 Kg
MakeSiemens
Pin Count60-pin controller-area network (CAN) cable
Connection Typeinterconnects the system power supplies, amplifier cards and the main processors of Control Panel

Minimum order quantity: 1 Piece

CCL

Cable tree feet Long

Model CCL from Siemens – Fire Safety is a 60-pin controller-area network (CAN) cable that is used for Siemens Modular (or FireFinder XLS) system communication.
Model CCL interconnects the system power supplies, amplifier cards and the main processors found at the top of Siemens Modular (or FireFinder) control panels.
Note: A length of 3-feet (91.4 cm.) is required for connection between the following: SCM-8 / LCM-8 / FCM-6 modules from Models CC-5 / CC-2 card cages; inner doors,
and row-to-row on Model CAB-series inner doors.
UL / ULC Listed; FM, CSFM Approved

Siemens FC924 US Cerberus PRO 504-Points Addressable Fire Alarm Control Panel

Request Callback

₹ 175000 / Piece Get Latest Price

View Brochure
Number of Zone8
Operating Voltage170 Watt Power Supply and standard operator interfaces
BrandSiemens
Log Capacity10,000-event history-logging capability
StandardUL 864 10th Edition Listed  UUKL Listing for smoke control  ULC-S527 Listed  FM, CSFM & NYC Fire
NetworkNetworkable up to 32 panels using CV Web or up to 16 panels using SafeDLink
SystemSupport 504 Addressable Device - One (1) to eight (8) ‘Class B’; one (1) to four (4) ‘Class A’ for M

Minimum order quantity: 1 Piece

The Cerberus PRO 504-point (Model FC924) addressable FACP is designed to meet the fire-protection needs of mid-size buildings. This advanced FACP offers features typically required in mid-size buildings in a package that is easy to install and competitively priced.
Additionally, FC924 is networkable, allowing the systems to fulfill the growing fire-protection needs of the building. The programming software for the 504-point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM).

Architect & Engineer Specifications Addressable fire alarm control panel (FACP) intended for mid-size building applications Comprised of the following system components: Operating units Periphery boards Power supplies System enclosures ‘Walk Test’ System features: Supports 504 addressable devices:- One (1) to eight (8) ‘Class B’; one (1) to four (4) ‘Class A’ for Model FC924 10,000-event history-logging capability Includes one (1) ‘Class A’ or two (2) ‘Class B’ notification appliance circuits (NACs) Resettable and non-resettable 24VDC, [nominal] auxiliary power Connectivity to a leased-line / city-tie module Releasing module supports activation of releasing valves in pre-action / deluge systems / agent release Off-normal warning message prior to reset Fast and easy set-up with auto-configuration feature Networkable up to 32 panels using CV Web or up to 16 panels using SafeDLink Cerberus® DMS Danger Management Station can monitor and control up to 32 Models FC924 FACPs Supports multiple global displays Digital alarm communication transmitter (DACT) UL 864 10th Edition Listed UUKL Listing for smoke control ULC-S527 Listed FM, CSFM & NYC Fire Department Approved

Siemens FHK2002-R3 Enclosure Kit 2 Height Units 1 Window Red (for FC922 FC924)

Request Callback

₹ 34780 / Piece Get Latest Price

View Brochure
BrandRavel
System TypeAddressable
Number of Zones2 Zone
StandardUL 864 9th Edition Listed, ULC Listed
MakeSiemens
Net Weight0.453 Kg
ColourRed
ModelFHK2002-R3
ApprovalFM, CSFM and NYC Fire Dept. Approved

Minimum order quantity: 1 Piece

FHK2002-R3

Enclosure Kit 2 Height Units 1 Window Red (for FC922 FC924)

Red 2 Height Unit 1 Window Enclosure kit (for FC922, FC924) Consists of: One FHB2002-R1, one FHD2004-U1, one FHD2006-U1, one FHD2002-R3

Siemens FC922 US Cerberus PRO 252-Point Addressable Fire Alarm Control Panel

Request Callback

₹ 120000 / Piece Get Latest Price

View Brochure
Usage/ApplicationCommercial
Model Name/NumberSiemens FC 922US 252-Points Addressable Fire Alarm Control Panel
Power170 Watt Power Supply and standard operator interfaces.
Installation ServiceYes
Installation ChargesExtra as per Actuals
System FeatureSupports 252-to-504 addressable devices: - One (1) to four (4) ‘Class B’; one (1) to two (2) ‘Class
Log Capacity10,000-event history-logging capability

Minimum order quantity: 1 Piece

The Cerberus PRO 252-point (Model FC922) addressable FACP is designed to meet the fire-protection needs of mid-size buildings. This advanced FACP offers features typically required in mid-size buildings in a package that is easy to install and competitively priced.

Additionally, FC922 is networkable, allowing the systems to fulfill the growing fire-protection needs of the building. The programming software for the 252 point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM).

Architect & Engineer Specifications Addressable fire alarm control panel (FACP) intended for mid-size building applications Comprised of the following system components: Operating units Periphery boards Power supplies System enclosures ‘Walk Test’ System features: Supports 252 addressable devices:- One (1) to four (4) ‘Class B’; one (1) to two (2) ‘Class A’ for Model FC922 10,000-event history-logging capability Includes one (1) ‘Class A’ or two (2) ‘Class B’ notification appliance circuits (NACs) Resettable and non-resettable 24VDC, [nominal] auxiliary power Connectivity to a leased-line / city-tie module Releasing module supports activation of releasing valves in pre-action / deluge systems / agent release Off-normal warning message prior to reset Fast and easy set-up with auto-configuration feature Networkable up to 32 panels using CV Web or up to 16 panels using SafeDLink Cerberus® DMS Danger Management Station can monitor and control up to 32 Models FC922 FACPs Supports multiple global displays Digital alarm communication transmitter (DACT) UL 864 10th Edition Listed UUKL Listing for smoke control ULC-S527 Listed FM, CSFM & NYC Fire Department Approved

Siemens FH901-R3 Cerberus PRO 50-Point System Enclosure

Request Callback

₹ 15000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
Points Covered50 Points
MakeSiemens
ColourRed
ModelFH901-R3
Packaging Dimension45.90 x 41.80 x 13.00 cmt

Minimum order quantity: 1 Piece

FH901-R3

50 Point System Red Enclosure

The Model FH901-R3 enclosure for the 50-point addressable fire system (Model FC901) FACP supports all system modules, including 12AH battery power. The Model FH901-R3 enclosure is comprised of a dual-mounting setup that allows the main board to be partially mounted in a lower-to-upper position. Model FH901-R3 comes in red.

Siemens FC901-U3 50-Point Addressable Fire Alarm Control Panel(FACP)

Request Callback

₹ 64800 / Piece Get Latest Price

View Brochure
Number of Zone16
BrandSiemens
Points50 Points Addressable
ModelFC901-U3
ApprovalFM, CSFM & NYC Fire Department Approved
StandardUL 864 10th Edition Listed, ULC- S527 3rd Edition Approval

Minimum order quantity: 1 Piece

Model FC901 is an intelligent FACP that provides a cost-effective, feature-rich solution for small fire-alarm system applications.Small and compact in design, Model FC901 is ideal for small fire-protection applications using less than 50 addressable devices. Typical usages include retail outlets, strip malls, medical offices, restaurants, banks, etc.
Fire alarm control panel (FACP) for upto 50 addressable points that iscomprised of the following three (3)system components:Main board (Model FCM901-U3)6.5 Amps (170-Watt power supply Model FP2011-U1)System enclosure (Model FH901-U3 / R3)

Siemens TZC-8B Firefighter's Telephone Zone Card

Request Callback

₹ 56450 / Piece Get Latest Price

View Brochure
BrandRavel
System TypeAddressable
Number of Zones2 Zone
Circuit CountEight (8) firefighters’ telephone circuits
Circuit TypePower-limited circuits
StandardUL 864 9th Edition Listed & ULC Listed; FM, CSFM, & NYC Fire Department Approved
ToneCall-in Acknowledge tone & Command console Busy tone
Plug inPlugs into a Model CC-2 or Model CC -5 Card Cage

Minimum order quantity: 1 Piece

The Firefighter’s Telephone Zone Card (Model TZC 8B) is a FireFinder XLSV option module that plugs into a Model CC-2 or Model CC -5 Card Cage, providing up to eight (8) firefighter’s telephone zones. The zones have an ‘off-hook’ ‘acknowledge’ tone and a Command Console ‘busy’ tone. TZC-8B (Front View) TZC-8B (Side View) When the zone becomes active, the remote telephone station will receive an ‘off-hook’ ‘acknowledge’ tone, and the programmed zone light will begin flashing at the command console. Model TZC-8B also offers a means for emergency response personnel situated throughout the affected building to verbally communicate to one another during each emergency situation.

• Eight (8) firefighters’ telephone circuits
• Plugs into Model CC-2 or Model CC-5 Card Cage
• Call-in Acknowledge tone
• Command console Busy tone
• Warden Page option - Manual or automatic
• Power-limited circuits
• UL 864 9th Edition Listed & ULC Listed; FM, CSFM, & NYC Fire Department Approved.

Siemens LPB Local Page Board Cerberus PRO Modular System

Request Callback

₹ 42260 / Piece Get Latest Price

View Brochure
BrandRavel
System TypeAddressable
Number of Zones2 Zone
StandardUL864 | CAN / ULC Listed
MakeSiemens
ModelLPB - Local Page Board
Wiring TypeClass A’ (Style 7), via four (4) pairs of wires and Class B’ (Style 4), via two (2) pairs of wires
ChannelsTransmits eight (8) audio channels

Minimum order quantity: 1 Piece

The Local Page Board (Model LPB) is used to connect the microphone ─ mounted inside the Live Voice Module (Model LVM) ─ and the voice-internal telephone system. Model LPB serves as a plug-on board to Model DAC-NET, and converts the two (2) analog input signals into the system’s internal digital format

Siemens DAC Net Cerberus PRO Modular System Digital Audio Card

Request Callback

₹ 81000 / Piece Get Latest Price

View Brochure
System TypeAddressable
Number of ZonesSiemens
BrandSiemens
StandardUL864 | CAN / ULC Listed
Wiring`Class B’ (Style 4), via two (2) pairs of wires  `Class A’ (Style 7), via four (4) pairs of wires
ChannelsTransmits eight (8) audio channels
SourceAudio signal source
Communicationon-board microprocessor

Minimum order quantity: 1 Piece

The Digital Audio Card (Model DAC-NET) provides the audio source for the Cerberus PRO Modular Voice Evacuation System, and provides D-NET network communication to and from the Operator Interface (OI) and between enclosures.

Model DAC-NET is capable of transmitting eight (8) digital channels of audio, via two (2) pairs of wire. One (1) DAC-NET is required in each Cerberus PRO Modular voice-panel enclosure, and can be wired `Class A’ (Style 7) – four (4) pairs of wires, or `Class B’ (Style 4) – two (2) pairs of wires.
Additionally, Model DAC-NET, which plugs into one (1) slot in the Model CC-5 or Model CC-2 Card Cage, has on-board light-emitting diodes (LEDs) for system status and troubleshooting.

 Audio signal source On-board microprocessor Built-in, ground-fault detection Transmits eight (8) audio channels Programmable, custom messages or tones Five (5) minutes of message / tone-storage memory Provides communication of 99 types, max., of the following modules, via the CAN bus: SCM-8 LCM-8 FCM-6 FMT `Class B’ (Style 4), via two (2) pairs of wires `Class A’ (Style 7), via four (4) pairs of wires UL864 | CAN / ULC Listed

Siemens SSD-C System-Status Display Series Field Mounted Remote LCD Display with control

Request Callback

₹ 49550 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeStatus Display
StandardUL864 & CAN / ULC-S576 Listed
LedAudible and event-status light-emitting diodes (LEDs)
ButtonsScroll buttons to view additional events
Wiring TypeSupports ‘Class B’ or ‘Class A’ wiring
ApprovalsFM Approved

Minimum order quantity: 1 Piece

The System-Status Display (SSD Series) is a remote light-emitting diode (LED) / liquid-crystal display (LCD) display unit that shows the local status of a Cerberus PRO Modular system. A LED will illuminate when Alarm | Supervisory | Trouble and Security events occur on the system. A (4) four-line LCD will give details of the event in alphanumeric form. The display can be toggled to display additional events. Optional remote-system-control capabilities are available.

Siemens CAB2 Two-Row Enclosure Cerberus PRO Modular Enclosures and Equipment

Request Callback

₹ 79000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of Zones2 Zone
Size45" (114.3cm.) high, 26" (66cm.) wide, and 8" (20.3cm.) deep.
ColourBlack
Net weight22.230 Kg
MakeSiemens
ModelCAB2-BB

Minimum order quantity: 1 Piece

Model CAB2 is the mid-sized Cerberus PRO Modular enclosure capable of housing a maximum two (2) Model CAB-MP cabinet mounting plates.
The inner door has two (2) rows of four (4) mounting slots. The outer door has space for mounting two (2) outer door plates (Models OD-LP, OD-BP or OD-GP). The outer door can be configured to open from either side.
Model CAB2 consists of the Model CAB2-BB back box; the Model CAB2-BD black inner and outer door package, and one (1) Model OD-LP lens plate.

The outer door has a single lock and key set installed. Red doors are available in Model CAB2-RD.

Additional door mounting plates must be ordered separately. Approximate size is 45" (114.3cm.) high, 26" (66cm.) wide, and 8" (20.3cm.) deep

Siemens ID-SP - Inner Door Single Module Blank Plate (two per package) Cerberus Pro Modular System

Request Callback

₹ 3700 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
MakeSiemens
Net weight1.268 Kg
Packaging Quantity1
Country of originUnited States of America
ModelID-SP

Minimum order quantity: 1 Piece

Inner Door Single Module Blank Plate (two per package)

Model ID-SP is a single-module inner-door enclosure mounting plate used with Siemens Modular (or
FireFinder) systems.

Two plates are shipped per package.

Siemens CC 2 Card Cage 2 Slots Cerberus PRO Modular System

Request Callback

₹ 10000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
StandardUL864 & CAN / ULC-S576 Listed
SlotsCard Cage-2 Slots
MakeSiemens
Compatibilitymmon card cage for all Cerberus PRO Modular system fire-and-voice option cards
Connection TypeAll cards communicate via common 60-pin power / data bus

Minimum order quantity: 1 Piece

The Model CC-2 card cage provides the physical mounting location and all wiring connection points for all fire and voice system options cards for the Cerberus PRO Modular system.

All cards plugged into the Model CC-2 card cage communicate with other Cerberus PRO Modular system modules via a common 60-pin data bus. This 60-pin bus runs through the card cage, making all communication data buses and signals available to all cards.
Connectors are provided on the left & right side of the Model CC-2 to connect a 60-pin cable for communications with the Cerberus PRO Modular system’s operator interface, power supplies and amplifiers modules. There are no active components on Model CC-2.
Field wiring to all devices and circuits terminates on the Model CC-2 card cage. All cards designed for use with the Model CC-2 route their field wiring terminations to the `top’ of Model CC-2 – these connections are all power-limited.
Internal wiring connections distribute 24VDC to cards or high-level audio signals (depending on application used) connect to the `bottom’ of Model CC-2 – these connections are all non-power limited.
All wiring connections to Model CC-2 are to removable terminal blocks. Terminal blocks are rated for use with wire-sized 12AWG to 24AWG. Each terminal block comes with a protective cover that also serves as a handle to allow easy terminal-block removal when wires are connected.
Each connector is numbered to make wiring terminations to the correct position on the terminal block simple and reduce the potential for wiring errors

Siemens CC-5 Card Cage 5 Slots Cerberus PRO Modular System

Request Callback

₹ 15000 / Piece Get Latest Price

View Brochure
System TypeAddressable
Number of ZonesSiemens
BrandSiemens
Mounting TypeMounts on back box or Model CAB-MP (two-module spaces)
StandardUL864 & CAN / ULC-S576 Listed
Slots5 Slots
Connection TypeAll cards communicate via common60-pin power / data bus
CompatibilityCommon card cage for all Cerberus PRO Modular system option cards

Minimum order quantity: 1 Piece

The Model CC-5 card cage provides the physical mounting location and all wiring connection points for all fire and voice system options cards for the Cerberus PRO Modular system fire alarm control panel (FACP).

Specifications

All cards plugged into the Model CC-5 card cage communicate with other modules of the Cerberus PRO Modular system panel ─ via a common, 60-pin data bus.
This 60-pin bus runs through the card cage; making all communication data buses and signals available to all cards. Connectors are provided on the left and right side of Model CC-5 to connect a 60-pin cable for communications with the Cerberus PRO Modular system operator interface, power supplies and amplifiers modules.
There are no active components on Model CC-5.
Field wiring to all devices and circuits terminates at the Model CC-5 card cage.
All cards, which are designed for use with Model CC-5, route their field wiring terminations to the ‘top’ of Model CC-5. These connections are all power-limited.
Internal wiring connections distribute 24VDC to cards or high-level audio signals (depending on application used) connected to the ‘bottom’ of Model CC-5. Though, these internal-wiring connections are all non-power limited.
All wiring connections to Model CC-5 are made to removable terminal blocks. Terminal blocks are rated for use with wire-sized 12AWG to 24AWG. Each terminal block comes with a protective cover that also serves as a handle to allow easy terminal-block removal when wires are connected.
Each connector is numbered to make wiring terminations to the correct position on the terminal block simple and reduce the potential for wiring errors.

Siemens MCP - Red Fire Detection System Control Units - Manual Call Point

Request Callback

₹ 695 / Piece Get Latest Price

View Brochure
TypeAddressable
BrandSiemens
Usage/ApplicationFire Alarm System
Model Name/NumberMCP Red
Working VoltageDC 16…26 V
ColorRed
Weight0.144 Kg
ShapeSquare

Minimum order quantity: 1 Piece

Siemens MCP - Red Fire Detection System Control Units - Manual Call Point

- Manual call point to all fire detection system control units with collective detectorevaluation

- For surface mounting suited for wet, humid and dusty areas

- Two-wire installation


Siemens HI921 Thermal / Heat Detector, Cerberus PRO Detectors and Peripherals

Request Callback

₹ 2050 / Piece Get Latest Price

View Brochure
Detection TypeFixed temp
System CompatibilityConventional
Alarm Temperature57°C
MaterialABS
TechnologyBuilt-in ISOtechnologyTM
CompatibiltyCompatible with Siemens Model `H’ - series devices on the same loop
Temperature RangeContains seven (7) field - selectable settings in a temperature range of 135  F 17 5  F (57.2  C
LEDTri - color detector status light emitting diode (LED) with 360 ° view
ComplyRestriction of Hazardous Substances (RoHS compliant)
StandardUL 521 Listed, ULC Listed
ApprovalCSFM (# 7272 0067:0258 ) Approved

Minimum order quantity: 1 Piece

The Intelligent Thermal (Heat) Detector (Model HI921) provides an advanced method ofdetection, address programming supervision ─ combined with sophisticated FACP communication. Model HI921 uses a state of the art thermistor, microprocessor andadvanced signal analysis, providing high reliability and accuracy.
Additionally, Each Model HI921 unit is UL listed including advanced built-in ISOtechnologyTM - a “True Class-X” SLC operation (use is optional) greatly improving system reliability and circuit integrity while providing advanced addressable fault finding.

Each model HI921 is a cost effective, intelligent , addressable thermal detector thatprovides distinctive, advanced feature s : seven (7) field selectable temperature settingsspecially tailored for application specific detection needs combined with Class X SLCoperation built in avoiding additional installation and material cost

The temperature range settings for each Model HI921 detector is between 135°F (57°C) ─17 5 °F (79°C) with fixed and rate of rise programmability . This variance provides thecustomer with maximum flexibility to program the temperature settings to suit multipleapplication needs and changing environmental conditions

Siemens XDLC Cerberus PRO Modular System Device Loop Card

Request Callback

₹ 23650 / Piece Get Latest Price

View Brochure
Number of Zone8
BrandSiemens
PointsSupports up to 252 addressable points
TechnologyPolarity insensitive (in non-isolation mode) via SureWire™ technology
LEDQuantity 16 diagnostic light-emitting diodes (LEDs) for easy circuit diagnosis
CircuitOperates and maintains all devices residing on up to four (4) `Class A’, eight (8) `Class B’

Minimum order quantity: 1 Piece

The Siemens – Fire Safety `Class X’ Device Loop Card (Model XDLC) is the interface used for connecting Siemens addressable, intelligent `X’ as well as `H’-series devices.

Each Model XDLC plugs into one (1) slot of the Model CC-2 or Model CC-5 card cage.

Programming for Model XDLC is accomplished via the Cerberus PRO Modular system custom-configuration tool, Zeus-C. Model XDLC takes one (1) address on the network, communicating up to a total 252 detectors and devices. Model XDLC has 16 LEDs for diagnostic purposes, and provides ground-fault detection and zone-isolation circuitry.

Architect & Engineer Specifications Supports up to 252 addressable points Operates and maintains all devices residing on up to four (4) `Class A’, eight (8) `Class B’ addressable circuits Compatible with Siemens intelligent, addressable ‘X’ and ‘H’-series devices:- Multi-criteria / Carbon Monoxide (CO) Detector with ASAtechnologyTM- Multi-criteria Detector with ASAtechnologyTM- Multi-criteria Detector- Thermal (Heat) Detector- Input / Output Interface Module Polarity insensitive (in non-isolation mode) via SureWire™ technology:- Modern technology supports comprehensive system and interface communication Quantity 16 diagnostic light-emitting diodes (LEDs) for easy circuit diagnosis Microchip controls on-board isolators Device Programmer / Tester (Model DPU) programs and verifies device’s address:- programming capabilities include testing a duct detector, as well as other Siemens addressable devices Supports `Class B’ | `Class A’ | `Class X’ wiring Supports T-Tapping Degrade mode UL864 | CAN / ULC Listed FM Approved

Siemens Rembox 2 Cerberus PRO Modular Enclosures and Equipment Small Remote Lobby Enclosure

Request Callback

₹ 51000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Size14-1/2" (36.8cm.) wide, 18-1/2" (47cm.) high and 5" (12.7cm.) deep.
StandardUL 864 Listed, ULC Listed FM
Packaging dimensions (L x W x H)55.37 x 45.21 x 18.80 cmt
Net Weight8.710 Kg
Made inUnited States of America

Minimum order quantity: 1 Piece

Two-Module Remote Enclosure Model REMBOX2 has two (2) innerdoor module spaces, and can hold on Cerberus PRO Modular OI, up totwo (2) switch-module brackets, one (1) Model LVM. Combinations are permissible.
Model REMBOX2 can also mount a single Model RNI on a bracket included in the backbox.

A bracket (Model REMBOX2-MP) can be used to mount up to four (4) Model OCM-16s or Model SIM-16 enclosures.

Model REMBOX2-MP must be purchased separately.

Approximate size of Model REMBOX2 is 14-1/2" (36.8cm.) wide, 18-1/2" (47cm.) high and 5" (12.7cm.) deep.

Siemens ABHW-4B Detection Bases Intelligent Audible (Sounder) Base (with Loop-Power Option)

Request Callback

₹ 3999 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
Alarm BandHigh: ≥ 85 dB & Low:≥ 75 dB
StandardUL268, UL464 & UL2075 Listed; ULC-S525, ULC-S529 Listed
Audible AlarmYes
Wiring TypeInnovative two-wire, loop-power option
CompatibilityCompatible with Cerberus PRO intelligent detectors and Siemens ‘H’-series and ‘S’-series devices
ApprovalsFM (#3150, #3230 & #3010) and CSFM (#7300-0067:0271) Approved

Minimum order quantity: 1 Piece

The Model ABHW-4B Audible (Sounder) Base from Siemens Industry Inc. is an intelligent, supervised, and addressable detector base designed for use in standard applications requiring an audible notification device. Each Model ABHW-4B base generates a 3,000 Hz audio signal that complies with NFPA 72 Standard.

Architect & Engineer Specifications Innovative two-wire, loop-power option Supports Class-X SLC operation via Siemens ISOtechnology Highly flexible programming and configuration options with independently controlled outputs by device Provides six (6) field-configurable audible -tone patterns: Steady American National Standards Institute (ANSI) Temporal 3 ANSI Temporal 4 Carbon Monoxide [CO] Temporal 4 Low Power March time 120 (and Canadian March time 30) Power options include: NACs Loop (two-wire) Siemens PAD-series NAC Extenders Model ZIC-4A (for FireFinder XLS FACPs) Any other UL Listed, 24VDC regulated power supply Compatible with Cerberus PRO intelligent detectors and Siemens ‘H’-series and ‘S’-series devices Synchronization by loop Standard 3,000 Hz Buzzer tone UL268, UL464 & UL2075 Listed; ULC-S525, ULC-S529 Listed FM (#3150, #3230 & #3010) and CSFM (#7300-0067:0271) Approved

Siemens FDS183C-EN Audible & Visual Fire Alarm (Hooter cum Flasher)

Request Callback

₹ 2350 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
StandardGB 26851 – 2011
Audible AlarmYes
Operating voltageDC 24 V (Allowance range: 20 V…28 V)
Operating currentAlarm current ≤ 35 mA @ DC 24 V
Working conditionsTemperature: 0 °C…+55 °C, Relative humidity: ≤95% (40 °C, no condensing)
Flash rate1.0 Hz…2.0 Hz
S P L75 dB…120 dB
Modulation cycle1.0 s…2.6 s
Wire SystemTwo-wire system, power lines (24 V, 0 V)
Connection ModeConnect with fire alarm controller via I/O module

Minimum order quantity: 1 Piece

The audible and visual fire alarm FDS183C-EN can send audible and visual alarm signals when connected with a DC 24 V power supply. It can be used with bus fire alarm controller via I/O module, and also can be combined with gas fire alarm to create a gas fire alarm system. When an accident occurs, the I/O module receives the start signal from the controller and drives the audible and visual alarm to send dazzling flashing signals and harsh audible alarm signals that alert the field personnel to quickly understand the occurrence of a fire on site and take measures for evacuation as soon as possible, thus avoiding major accidents.

FDS183C-EN is designed for audible and visual alarm at the scene of accident, and can be used in public space, hotels, entertainment venues, factories, shopping malls, hospitals, schools, office buildings, stock exchanges and other places, especially the locations with low visibility or smoke production.


Siemens RNI - Remote Network Interface, Cerberus PRO Modular System

Request Callback

₹ 19000 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
Mounting TypeConnects equipment mounted in a remote lobby enclosure to Cerberus PRO Modular system
StandardUL864 & CAN / ULC-S576 Listed
Wiring TypeSupports `Style 4’ or `Style 7’ wiring  CAN wiring: `Style 4’ only
ProtocolsCommunicates via H-Net | X-Net and CAN protocols
TempratureRange of 120+/-3°F (49+/-2°C) to 32+/-3°F (0+/-2°C)
Protection TypeBuilt-in transient protection

Minimum order quantity: 1 Piece

The Remote Network Interface (Model RNI) provides a remote-connection point for equipment mounted within the lobby enclosure of the Cerberus PRO Modular system fire alarm control panel (FACP). Model RNI is also used to provide additional remote input, output and control features to each Cerberus PRO Modular system FACP.

 Connects equipment mounted in a remote lobby enclosure to Cerberus PRO Modular system Built-in transient protection Communicates via H-Net | X-Net and CAN protocols Supports `Style 4’ or `Style 7’ wiring CAN wiring: `Style 4’ only Local sounder included Supports remote enclosure tamper switch UL864 & CAN / ULC-S576 Listed

Siemens BCL 42 Inch (60 Pin) Cable Long

Request Callback

₹ 5100 / Piece Get Latest Price

System TypeAddressable
Size2-Inch (60 Pin) Cable Long
BrandSiemens
StandardUL, ULC Listed
MakeSiemens
Length42-Inch (60 Pin) Cable Long
ModelBCL
Weight0.160 kg
Country of OriginUS

Minimum order quantity: 1 Piece

BCL

42-Inch (60 Pin) Cable Long

Model BCL is a required 42-inch (107 cm.) 60-pin cable used in Model CAB2,2X and Model CAB3,3X enclosures of Siemens Modular (or FireFinder) systems for row-to-row connections.
Model BCL is UL, ULC Listed.

Siemens SCM-8 Switch-Control Module Cerberus PRO Modular

Request Callback

₹ 25000 / Piece Get Latest Price

View Brochure
Control Module TypeSwitch-Control Module
Input Voltage24 V
Switch CountEight (8) programmable switches (ModelSCM-8)
MakeSiemens
IndicationLED indication of fan status(`ON’ / `OFF’ / `Trouble’)

Minimum order quantity: 1 Piece

Model SCM-8 is a Siemens Cerberus PRO Modular system option module that provides manual control of the emergency voice-evacuation or manual fire-system control. Each Model SCM-8 module provides eight (8) momentary push-button switches and 16 light-emitting diodes (LEDs) to indicate their status.

Each switch is assigned two (2) LEDs and a label to indicate the switch's programmed usage. The label slides behind a clear, protective membrane. One of the LEDs assigned to each switch is a dual-color LED used to indicate what type of signal is active. This LED may also be lighted steady or flashing to further indicate system status.
For example, zones active to the evacuation audio channel will have the LED lighted RED and steady; zones active to the `Alert’ audio channel will have the LED lighted RED and flashing; zones selected for paging will have the LED lighted GREEN and flashing until the microphone key is pressed.
When the zone-transfer confirmation message is received by the Cerberus PRO Modular system-command console, the LED will change to steady GREEN, indicating that it is clear to page. Telephone zones with an incoming call in progress will have an LED flashing GREEN until selected at the command console ─ at which time the LED will change to steady GREEN, etc. This process allows the operator easy, clear access to the overall system condition at all times. The second LED is AMBER, and is used to indicate a fault condition.
Each Model SCM-8 switch module is fully programmable, and may be used to control speaker circuits and a wide range of general system functions such as: `All Call’, `All Evac’, `Warden's Page’, `Speaker’, etc. Any number of circuits may be grouped and controlled by a single switch. Switch usage and zone groupings are assigned using the Zeus-C system programming software.
Each Model SCM-8 module is mounted on a hinged panel as a part of the Cerberus PRO Modular system command console enclosure.

Siemens OOHC941 multi-criteria Fire, CO Detector with ASAtechnology, Dual Optical,Heat,CO

Request Callback

₹ 9400 / Piece Get Latest Price

View Brochure
Alarm Sensor TypeMulti Criteria Fire and CO Detector
Operating Temperature+32° – +120°F(0° – +49°C)
Brand/CompanySiemens
Standards / ApprovalsUL 268 7th edition Listed, ULC Listed; FM (#3230, #3210), CSFM (#7272-0067:0258) Approved
LED TypeTri-color detector-status light-emitting diode (LED) with 360 ° view

Minimum order quantity: 1 Piece

Model OOHC941 is an advanced, multi-criteria fire | CO detector that incorporates a redundant optical / thermal sensor. Additionally, Model OOHC941 incorporates ASAtechnologyTM a distinctive forward / backward, light-scattering technology that provides high-tech, unparalleled fire detection to the widest range of fire types allowing the detector to distinguish non-threatening deceptive phenomena.

 UL 268 7th edition Listed, ULC Listed; FM (#3230, #3210), CSFM (#7272-0067:0258) Approved Built-in ISOtechnologyTM Competitive 10-year CO sensor lifetime Advanced multi-criteria fire detector that has optical thermal and CO sensors Differentiates between deceptive phenomena and an actual fire (nuisance-alarm avoidance) Compatible with Siemens Model `H’-series devices on the same loop (with Cerberus PRO fire-alarm control panels [FACPs]) Enhanced detection via forward-and-backward light-scattering technology Supervisory feature for temperature and CO-concentration-threshold monitoring Complies with NFPA 76 (Telco standard) as `VEWFD’ high-sensitivity detector UL Listed and FM Approved as a multi-criteria and `VEWFD’ fire detector Low-temperature warning for sprinkler systems, per NFPA 25 UL 268A Listed for direct air-duct use (4,000 FPM) UL 2075 and NFPA 72 requirements for sensitivity self-monitoring Remote sensitivity-measurement capability Tri-color detector-status light-emitting diode (LED) with 360 ° view Polarity insensitive via SureWire™ Responds to both flaming and smoldering-fire signatures Supervisory temperature-monitoring feature Automatic environment compensation Meets UL, NFPA 72 requirements for sensitivity self-monitoring Compatible with:- Model DB-11—series mounting bases- Model DPU (device programmer / loop tester) Restriction of Hazardous Substances (RoHS compliant)

Siemens FMT Fireman Master Telephone Cerberus PRO Modular System

Request Callback

₹ 50300 / Piece Get Latest Price

View Brochure
System ComponentFireman Telephone
System TypeSiemens
Mounting TypeRack Mount
TypeFirefighters’ Master Telephone
Model Name/NumberFMT
ColorRed
MakeSiemens
StandardUL864 & CAN / ULC-S576 Listed
ToneGenerates Acknowledge tone and Busy signal for remote telephones
LedDiagnostic light-emitting diodes (LEDs)

Minimum order quantity: 1 Piece

The Firefighters’ Master Telephone Module (Model FMT) provides firefighters with an emergency telephone system for communication with remote locations. Model FMT mounts to the rear of the inner door of a Model CAB 1 | Model CAB2 | Model CAB3 | or Model REMBOX4 enclosure, and includes a handset for the operator of the telephone system.

The Cerberus PRO Modular Systems firefighter’s telephone unit is designed for maximum performance in communication quality. Model FMT circuitry allows the master telephone and at least five (5) telephone stations to be off-hook, simultaneously, with no degradation of audio quality.

Siemens DPU Device Program Unit Fire Alarm System Devices Accessories

Request Callback

₹ 88000 / Piece Get Latest Price

View Brochure
Accessory TypeDevice Programmer Unit
System TypeAddressable
Mounting TypeMount not Needed
Operating Voltage12 V DC
Enclosure ProtectionIP65
Sound Level0db
Model Name/NumberDPU - Device Program Unit
BrandSiemens
FeaturesPrograms and addresses devices - compatible with various Siemens Fire Safety control panels
StandardUL Listed, ULC Listed
Battery BackupUp to four hours continuous use on fully charged batteries
Operating TypeServes as a loop tester and ground-fault detector
MakeSiemens

Minimum order quantity: 1 Piece

The Device Programmer / Test Unit (Model DPU) is a powerful programming / test tool that expedites installation of devices used on Siemens 50-point | 252-point | 504-point addressable systems, as well as FireFinder and MXL panels.

A portable, compact, and menu-driven component, Model DPU programs addresses into FACP-compatible devices, and tests them to ensure proper operation prior to installation.

Prior to connecting a device circuit to the control panel, the loop from Model DPU can be operated (AC power must be used for this operation).This looping process shall allow for ground-fault detection, as well as debugging the circuit.

Siemens XMS-S, Single Action Manual Pull Stations - Addressable & Conventional Models

Request Callback

₹ 4425 / Piece Get Latest Price

View Brochure
ActionSingle Action
Brand/CompanySiemens
ColourRed
CompatibleCompatible with current Siemens Fire Alarm Control Units (FACU’s)
MountingMinimal mounting depth allowing compatibility with standard single gang electrical boxes in retrofit
TypeRoHS compliant

Minimum order quantity: 1 Piece

The XMS-Series of manual pull stations are a complete addressable and conventionalpull station portfolio - single action

The addressable versions feature built-in Class X (Style 7) isolationcapability for increased system survivability.

All models feature a T-45 reset key to match the fire alarm panel enclosure.

Addressable models also feature a tri-color status LED to indicate normal, alarm, and trouble status.

All models utilize one address.

The manual stations can be commissioned to operate in non-isolation (polarityinsensitive) or isolation with Class X mode of operation.

Siemens PFT Portable Firefighters Telephone, Cerberus PRO Modular System

Request Callback

₹ 8200 / Piece Get Latest Price

View Brochure
System ComponentFireman Telephone
System TypeSiemens
Mounting TypeRack Mount
StandardUL864 & CAN / ULC-S576 Listed
ModelPFT - Portable Firefighters’ Telephones
ColourRed
MakeSiemens
Net weight0.180 Kg

Minimum order quantity: 1 Piece

Models PFT Portable Firefighters’ Telephones is available for field connection to the emergency telephone system. Each phone consists of a rugged, high-impact plastic handset with a red coiled phone cord attached. A ¼” (0.6 cm.) phone-plug assembly is attached to the end of the phone cord for connection to the field-mounted phone jacks.

Siemens FJ-303 Firefighters Jack with Flying Leads Remote FirefightersTelephones & Accessories

Request Callback

₹ 3050 / Piece Get Latest Price

View Brochure
BrandSiemens
System TypeAddressable
Number of ZonesSiemens
MakeSiemens
ColorRed
Packaging dimensions26.67 x 15.24 x 5.08 cmt
Net weight0.091 Kg
Country of originUnited States of America

Minimum order quantity: 1 Piece

Remote Telephone Jacks

The Remote Telephone Jack FJ-303 is connected to the emergency tele-phone system.

They are wired to the telephone zone circuits on the Telephone Zone Card (Model TZC-8B) located in the FireFinder XLS system enclosure.

There is no limit to the number of remote telephone jacks that can be connected to a single telephone zone circuit.

The remote telephone jacks are mounted to a single gang electrical box.

Models FJ-303 have flying leads connected to the phone jack

Models FJ-303 have a red baked-enamel finish with a white, silk-screened telephone handset icon on them

Siemens NIC-C Cerberus PRO Network Interface Card

Request Callback

₹ 32000 / Piece Get Latest Price

View Brochure
Card TypeNetwork Interface Card
Interface TypeNetwork Interface
Usage/ApplicationSupports `Class B’ – (Style 4) or `ClassA’ ─ (Style 7) wiring for XNET or HNET
Operating TemperatureRange of 120+/-3°F (49+/-2°C) to 32+/-3°F (0+/-2°C)
TypeNetwork repeater
NetworkSupervises the HNET or XNET and CANnetworks
Wiring TypeSupports `Class B’ – (Style 4) or `ClassA’ ─ (Style 7) wiring for XNET or HNET

Minimum order quantity: 1 Piece

The Network Interface Card (Model NIC-C) provides HNET or XNET network communications between enclosures. In addition to the HNET or XNET communication, Model NIC-C provides CAN network communication within an enclosure or external to the enclosure. The HNET or XNET can be wired `Class B’ – Style 4 or `Class A’ - Style 7, but the CAN network can only be wired `Class B’ - Style 4.

HNET communicationsXNET communicationsCAN network communicationsSupports `Class B’ – (Style 4) or `ClassA’ ─ (Style 7) wiring for XNET or HNETSupervises the HNET or XNET and CANnetworksDiagnostic light-emitting diodes(LEDs)Isolates short circuit faultsGround-fault detectionNetwork repeaterDownloadable firmwareUL864 | CAN / ULC Listed FM,

Siemens XTRI R Addressable Output Model Intelligent Device Interface Module

Request Callback

₹ 3620 / Piece Get Latest Price

View Brochure
Number of Zone1
BrandSiemens
StandardUL864 | UL2572 | UL2017 Listed; CAN/ULC - S527 & CAN/ULC S576 Listed - File S24304, Vol. 3
ApprovalsFM Approved
LEDMulti - color light emitting diode (LED) indicates system status: GREEN, AMBER, RED
MountMounts in a 4 inch (10.2 cm.) square, 2 ¼” (5.7 cm.) deep single gang or double gang back box

Minimum order quantity: 1 Piece

The Siemens Fire Safety XTRI series I ntelligent I nterface Modules are designed toprovide the means of interfacing direct shorting devices to the fire alarm controlpanel (FACP) SLC. All modules take up one (1) address on the loop.

Each XTRI series interface module provides the “built in” ISO technology featureintelligent dual isolation meeting NFPA 72 Class X (Style 7) wiring requirements.Up to 252 isolators per loop and up to 30 devices between isolators (wired inpolarity insensitive mode). Additionally, the devices between isolators can eitherbe ‘H’ series or the more contemporary ‘X’ series detection devices.

Siemens XTRI-S, Single Input Monitor Module with inbuilt Isolater, Intelligent Device Interface

Request Callback

₹ 2999 / Piece Get Latest Price

View Brochure
PhaseSingle Phase
Power Supply13VDC 32VDC
BrandSiemens
Humidity0 95% (non-condensing)
Model Name/NumberXTRI - S
Dimensions MmPackaging Dimension L 6.10 x W 8.90 x H 2.30 cmt
Weight0.095 Kg

Minimum order quantity: 1 Piece

The Siemens Fire Safety XTRI-series Intelligent Interface Modules are designed toprovide the means of interfacing direct shorting devices to the fire-alarm controlpanel (FACP) SLC. All modules take up one (1) address on the loop.

This single-input interface module can only monitor andreport the status of a N.O. or N.C. contact.

Siemens Mounting Detector Bases DB-11E Cerberus PRO Specialized Detection Devices

Request Callback

₹ 250 / Piece Get Latest Price

View Brochure
Board TypeAddressable
ShapeRound
Mounting TypeMount on a 4-inch octagon, square or single-gang electrical box
DiameterDimension of 4.5’’ (11.4 cm)
Compatible withModels OH921, OP921, OOH941, OOHC941 and HI92
TechnologySupports Isolation field wiring for ISOtechnology feature

Minimum order quantity: 5 Piece

The detector bases are low-profile, surface mounting bases used with various Siemens – Fire Safety conventional and addressable detectors.

 Supports Isolation field wiring for ISOtechnology feature
 Functions with the addressable Models OH921, OP921, OOH941, OOHC941 and HI921 intelligent detectors
 Compatible with Model ‘H’, “11” and “121” series of conventional detectors
 Model DB-11E mount on a 4-inch octagon, square or single-gang electrical box
 UL268 Listed, ULC-S529 Listed
 FM, CSFM and NYC Fire Department Approved

Siemens XTRI-D, Dual Input Monitor Module with inbuilt Isolater, Intelligent Device Interface Module

Request Callback

₹ 5500 / Piece Get Latest Price

View Brochure
PhaseDual Phase
Power Supply13VDC-32VDC
BrandSiemens
Humidity0 95% (non-condensing)
Model Name/NumberXTRI - D
CompliantRestriction of Hazardous Substances (RoHS) compliant
StandardUL864 | UL2572 | UL2017 Listed; CAN/ULCS527 & CAN/ULC-S576 Listed - File S24304, Vol. 3

Minimum order quantity: 1 Piece

The Siemens Fire Safety XTRI-series Intelligent Interface Modules are designed to provide the means of interfacing direct shorting devices to the fire-alarm control panel (FACP) SLC. All modules take up one (1) address on the loop.

Model XTRI-D is a dual-input module that is designed to supervise and monitor two (2) sets of dry contacts.

Model XTRI-D only requires one (1) address, but responds independently to each input.
Model XTRI-D is ideal for monitoring a water-flow switch and its respective valve tamper switch.


 

Siemens FCM-6 Fan-Control Module Cerberus PRO Modular System

Request Callback

₹ 35636 / Piece Get Latest Price

View Brochure
Control Module TypeFan Control Module
SwitchesSix (6) sets of the push-button, programmable fan-control switches
MonutingRemote mounting in Model REMBOX2or REMBOX4 enclosures
StandardUL864 & CAN / ULC-S576 Listed
Control Typemanual control of building heating | ventilation | air-conditioning (HVAC) system fans and dampers
Current (Standby)14mA Max + 1mA (per active LED)

Minimum order quantity: 1 Piece

Model FCM-6 is a Cerberus PRO Modular system command-console option module that provides manual control of building heating | ventilation | air-conditioning (HVAC) system fans and dampers. Each Model FCM-6 module provides six (6) sets of three (3) push-button switches for manual system control. Each switch has three (3) associated LEDs to indicate Fan / Damper status: `OFF’ (RED LED), `ON’ (GREEN LED), `TROUBLE’ (YELLOW LED).
When in the automatic position, the RED and GREEN LEDs indicate Fan / Damper status (`ON’ / `OFF’) based on the system logic that can be programmed to automatically control the fan outputs.

When manually switched to the `OFF’ position, the RED LED will flash, indicating the output circuit used to turn off the Fan / Damper has activated. The RED LED will light a steady stream of RED to indicate positive feedback of the Fan / Damper actually turning off (via a monitored input). When manually switched to the `ON’ position, the GREEN LED will flash, indicating the output circuit used to turn on the Fan / Damper has activated. The GREEN LED will light to a steady GREEN to indicate positive feedback of the Fan / Damper actually turning on (via a monitored input.)

Siemens GPMI-2-HW-KEY Software Upgrade Kit for Model PMI-2 Global Functionality

Request Callback

₹ 52000 / Piece Get Latest Price

BrandSiemens
System TypeAddressable
Number of ZonesSiemens
MakeSiemens
ModelGPMI-2-HW-KEY
Packaging Dimension15.24 x 2.54 x 1.27 cmt
Net Weight0.400 Kg
Quantity Unit1 No's

Minimum order quantity: 1 Piece

GPMI-2-HW-KEY

Software Upgrade Kit for Model PMI-2 Global Functionality

Model GPMI2-HW-KEY from Siemens Fire Safety is a software-upgrade kit that provides global functionality for a panel's central processor, via annunciating and controlling multiple Siemens Modular (or FireFinder) XLS panels. Each Model GPMI2-HW-KEY is UL864 10th Edition Listed, CSFM and NYCFD Approved.

Siemens OD-LP Outdoor Lens Plate Cerberus PRO Modular Enclosures and Equipment

Request Callback

₹ 6000 / Piece Get Latest Price

View Brochure
System TypeAddressable
Number of ZonesSiemens
BrandSiemens
Display TypeClear Plastic
MakeSiemens
Packaging Dimension52.07 x 38.10 x 1.27 cmt
Net Weight1.090 Kg
Country of OriginUnited States of America

Minimum order quantity: 1 Piece

Model OD-LP is a clear plastic lens plate mounted on the outer door of a system cabinet.

Model OD-LP is used to allow operators to see the system interface and controls mounted on the inner door, but restricts access to unauthorized users.

Model OD-LP covers an entire row on the outer door.

A single lens plate is included with each Model OD-LP
X

Contact Us

Roopesh Jetli (Owner)
Ikon Security & Automation
First Floor, C-102, JMD Garden, Sohna Road, Islampur
Gurugram - 122018, Haryana, India

Get Directions
Send Email
Share: